Heat Exchangers
Heat exchangers offer you a fresh look at an energy
management tool that is dust free, freeze resistant and easily maintained.
You are able to bring fresh air into the barn and recover heat that
you would otherwise need to supplement.
The
heat exchanger units feature a wash system, indoor & outdoor
drainage, removable core, variable speed control and automatic electronic
defrost.
| Model |
Width
inches (mm) |
Height
inches (mm) |
Electrical Requirements |
| RA400 |
14.5 (370) |
22.5 (575) |
115VAC |
2.4 Amps |
225 Watts |
| RA402 |
14.5 (370) |
22.5 (575) |
230VAC |
1.2 Amps |
225 Watts |
| RA1000 |
22.0 (560) |
29.5 (750) |
115VAC |
3.6 Amps |
368 Watts |
Heat Recovery Case Studies:
The Prairie Agricultural Machinery Institute has
tested Del-Air's heat exchangers with the following results:
| |
RA400/402 |
RA1000 |
| Exhaust
Airflow cfm (m3/hr) |
400 (680) |
950 (1614) |
| Supply
Airflow cfm (m3/hr) |
298 (506) |
645 (1096) |
| Supply
Air Temperature °F (°C) |
35 (2) |
38 (3) |
| Defrost
Cycle min/hr |
8 |
8 |
| Auto-Wash
Frequency hr |
24 |
24 |
| Barn
Heat Exhausted btu/hr (kW) |
38500 (11) |
94600 (28) |
| Supply
Heat Recovered btu/hr (kW) |
15900 (5) |
32300 (9) |
| Energy
Efficiency % * |
41% |
34% |
| Moisture
Removed From Barn gal/day (L/day) |
44 (200) |
88 (400) |
| TYPICAL CONDITIONS: |
| Outdoor = -22°F (-30°C) 95% RH |
| Barn Environment = 68°F (20°C) 70% RH |
| Barn Static Pressure = -0.05 in wg (12 Pa) |
* PAMI Detailed Test Procedure T-TP-5.1 method
used. All data verified by independent test agency.
To download a brochure on HRVs, click
here.
For further technical details regarding product usage please click and go to our Product
Support page.
|